Photoeye detection of cue mark on pre-printed web or machine sync Vertical and lateral image position adjustable while running +/- 1/32nd inch (0.8 mm)
WEB WIDTH:
4 inches to 10.5 inches (102 mm to 267 mm)
SUBSTRATES:
12 lb. to 110 lb. bond paper, vellum, various pressure sensitive labels, foil clad, vinyl coated, synthetic papers, many other materials
DIAGNOSTICS:
Power up self test, fault monitoring and reporting while running, off-line RIP diagnostics Power Supply breakout terminals permit operator to check voltages while running.
ENVIRONMENTAL:
59 to 82 degrees F, 15 to 28 degrees C 35 to 65% Relative Humidity, Non-Condensing
POWER: